Teach function Description
Q
1
You can use the teach function “Q
1
” to teach in the target and reference
background for the “Object between sensor and background” (“ObSB (Back‐
ground)”) switching mode. In this case, a signal is output if the sensor no
longer sees this taught-in background. Thus the output acts as High Active
(see figure 14, page 32).
Q
1
not You can use the teach function “Q
1
not” “ to teach in the target and refer‐
ence background with inverted logic for the “Object between sensor and
background” (“ObSB (Background)”) switching mode. In this case, a signal
is output as long as the sensor detects the taught-in background. Thus the
output acts as Low Active (see figure 15, page 32).
6.4.1.3.3 Manual settings
Setting Description
Q
1
You can use the “Q
1
” setting to manually set the distance to the reference
background in millimeters for the “Object between sensor and background”
(“ObSB (Background)”) switching mode.
Q
1
hysteresis You can use the “Q
1
hysteresis” setting to manually set the switching hyste‐
resis in millimeters. More details on hysteresis see "Manuelle Einstellungen
DtO_Dx50-2".
Q
1
Logic You can use the “Q
1
Logic” to manually select whether the output is to
act as High Active (see figure 14, page 32) or Low Active (see figure 15,
page 32).
6.4.1.3.4 Operating examples via display: “Object between sensor and background” (ObSB) switching
mode
Select and activate the ObSB (Background) switching mode for Q
1
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
→ DtO (1point)
/ to → ObSB (Background)
→ Saved
to → RUN mode
Necessary default settings:
-
Factory setting:
DtO (1point)
Teach in the current distance as a reference background for ObSB mode for Q
1
in the menu
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/ to → Teach Q
1
→ Q
1
Align the sensor with the reference background
→ Saved
to → RUN mode
Necessary default settings:
Mode Q
1
= ObSB (Background)
Factory setting:
-
OPERATION 6
8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
33
Subject to change without notice