Teach in the current distance as a reference background for the inverted ObSB mode for Q
1
in
the menu
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/ to → Teach Q
1
→ Q
1
/ to → Q
1
not
Align the sensor with the reference background
→ Saved
to → RUN mode
Necessary default settings:
Mode Q
1
= ObSB (Background)
Factory setting:
-
Manually set the desired distance of the reference background for ObSB mode for Q
1
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/ to → Manual Q
1
→ Q
1
30000 (Note: 3 = flashing 3)
/ , / , / , / ,
/ to → distance to reference background in mm
→ Saved
to → RUN mode
Necessary default settings:
Mode Q
1
= ObSB (Background)
Factory setting:
30,000 mm
Manually switch the logic for Q
1
to “Low Active”
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/ to → Manual Q
1
→ Q
1
/ to → Q
1
Logic
→ High Active
/ to → Low Active
→ Saved
to → RUN mode
Necessary default settings:
Mode Q
1
= ObSB (Background)
Factory setting:
High Active
6 OPERATION
34
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK