6.4.7.3.1 Operating example via display: Display Off
Display Off
Operating example or steps:
RUN mode
→ Q
1
Output
/ to → Device
→ User level
/ to → Disply
→ On
/ to → Off
The display is switched off
→ Display Off appears when a pushbutton is pressed
Necessary default settings:
-
Factory setting:
On
Display On
Operating example or steps:
RUN mode
Press and hold for 5 seconds → Distance value
reappears
Necessary default settings:
Display = Off
Factory setting:
On
6.4.7.4 Reset factory settings
The DT50-2 Pro can be reset to its factory settings.
NOTE
Upon confirmation that the device has been reset to its factory settings, it carries out
a warm start. During the device restarting process, the distance sensor function is
temporarily deactivated.
6.4.7.4.1 Operating example via display: Reset factory settings
Reset factory settings
Operating example or steps:
RUN mode
→ Q
1
Output
/ to → Device
→ User level
/ to → Reset
→ No
/ to → Yes
→ SICK DT50-2
RUN mode
Necessary default settings:
-
Factory setting:
-
6.4.7.5 Behavior if no measurement is possible (NoMeasurement)
If a distance measurement cannot be run, an error is output. Possible causes of the
error:
■
The measuring object is outside of the measuring range.
■
The light signal received by the sensor is not strong enough.
■
The laser is switched off.
The sensor behaves as follows when the factory settings are active:
OPERATION 6