Type Value
Maximum encoder fre‐
quency
300 Hz
Operating elements 2 buttons
1
Optical indicators 16 LEDs (5 x status display, 10 x LED bar graph, 1 green/red
feedback spot)
Acoustic indicators Beeper
1
1
Not yet available in pre-installed Quality Inspection SensorApp
11.5 Ambient data
Type Value
Shock load EN 60068-2-27: 2009-05
Vibration load EN 60068-2-6: 2008-02
Ambient operating temper‐
ature
0 °C ... +50 °C
1
Storage temperature –20 °C ... +70 °C
1
1
Permissible relative humidity: 0% ... 90%, non-condensing