1. Switch off the supply voltage to the device.
2. Undo the screws (Torx TX6, captive) on the hinged cover and open the cover as
follows:
°
Carefully pull the upper edge of the cover away from the housing a little at the
level of the hinges on the side. Use both of the recesses on the inside of the
cover to do this.
°
Fold the cover upwards starting from the bottom edge.
3. Making sure it is in the correct position, insert the memory card into the slot until
it locks into place. When doing this, position the contacts so that they are facing to
the rear and upwards, see the card symbol on the device.
4. Close the hinged cover. Make sure that the cover is completely flush with the
housing.
5. Tighten the screws on the hinged cover again.
6. Switch on the supply voltage for the device.
Removing the memory card from the device:
NOTICE
Risk of damage to the memory card!
b
To avoid damaging the microSD memory card, make sure the device is de-ener‐
gized when you insert or remove the card. For this purpose, disconnect the device
from the supply voltage.
1. Switch off the supply voltage to the device.
2. Undo the screws on the hinged cover.
3. Making sure it is in the correct position, push the memory card into the slot until
it is released. When doing this, position the contacts so that they are facing to the
rear and upwards, see the card symbol on the device.
4. Remove the memory card.
5. Close the hinged cover. Make sure that the cover is completely flush with the
housing.
6. Tighten the screws on the hinged cover.
7. Switch on the supply voltage for the device.
3.4 SICK AppSpace
The InspectorP6xx product family is part of the SICK AppSpace ecosystem, which
consists of software tools and programmable sensors or devices. See figure 6 for an
overview of SICK AppSpace.
Support
Portal
PROGRAMMABLE DEVICES
TOOLS
APP DEVELOPERS
Sensor
AppPool
SensorApps
AM
AppManagerAppStudio
AS
Conference
Sensor Integration
Machine
Figure 6: SICK AppSpace
3 PRODUCT DESCRIPTION
18
O P E R A T I N G I N S T R U C T I O N S | InspectorP62x 8024439/1EJ6/2022-02 | SICK
Subject to change without notice