EasyManuals Logo

SICK InspectorP62 Series User Manual

SICK InspectorP62 Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
V
S
“Host 1”
Aux 1”
“Result 2”
“Result 1”
“CAN”
“Sensor 2”
“Sensor 1”
AUX
CAN bus
“Result 1”
“Result 2”
PLC
“External output 2
CDM420-0006
Connection module 6
“Host 1”
Aux 1”
RS-232
HOST/PLC
Further data
processing 8
PC
Configuration
Diagnostics
Image display
Interfaces 3
Device 2
“Ethernet” (Host 2/Aux 2), Image transfer 5
“USB” (Aux 3) 4, Image transfer 5
RS-232/RS-422
Ethernet
USB
“Host 2”
Ethernet
Aux 2”
Aux 3”
“Sensor 2”
“Sensor 1”
“External input 2”
“External input 1”
CMC600
1
ã
â
V
S
ß
= á
“External output 1”
à 9
7
Figure 33: Connection of the device to peripherals via CDM420-0006 (overview)
1
External trigger sensor
2
Device
3
Interfaces
4
USB interface (not supported)
5
Image transmission
6
Connection modules
7
Configuration, diagnostics or image display
8
Data further processing
9
External digital outputs (not supported)
ß
Supply voltage V
S
à
External digital inputs (not supported)
á
Optional CMC600 parameter cloning module to use the external digital inputs and outputs of the device (not sup‐
ported).
13.4.2 Wiring overview of the CDM420-0006
ANNEX 13
8024439//2019-06 | SICK O P E R A T I N G I N S T R U C T I O N S | InspectorP621
63
Subject to change without notice

Table of Contents