Ambient data
Ambient operating temperature –25 °C … +70 °C
Temperature change rate ≤ 1 °K/min
Storage temperature –25 °C … +70 °C
Area of application (IEC 60654-1) Class C; weather-protected area of application
Operating altitude ≤ 3,000 m above sea level
Relative humidity 50% at 70 °C (IEC 60947-5-2)
Vibration resistance 1 mm / 10 Hz … 55 Hz (IEC 60947-5-2)
Shock resistance In accordance with IEC 60947-5-2
EMC In accordance with IEC 60947-5-2, IEC
60947-5-3 and IEC 61000-6-7
Minimum distance between 2 safety switches see "Mounting", page 15
1)
The adhesive strip above the LED displays must not be removed in order to achieve the specified enclo‐
sur
e rating.
11.2 Table of weights
Table 19: Weight IME2S
Type code Weight in g
IME2S12-04B4DQ9 33
IME2S12-04N4DQ9 33
IME2S12-04B4DC0 18
IME2S12-04B4DW2 60
IME2S12-04N4DC0 18
IME2S12-04N4DW2 60
IME2S12-08N4DC0 18
IME2S18-05B4DC0 42
IME2S18-08N4DC0 38
IME2S18-08B4DC0 42
IME2S30-12B4DC0 102
IME2S30-15N4DC0 94
Table 20: Weight IQB2S
Type code Weight in g
IQB2S12-04B4DT0 17
IQB2S12-04B4DQ9 31
IQB2S12-04B4DW2 61
11 TECHNICAL DATA
28
O P E R A T I N G I N S T R U C T I O N S | IME2S, IQB2S 8023341/17AZ/2020-03-24 | SICK
Subject to change without notice

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK IQB2S and is the answer not in the manual?

SICK IQB2S Specifications

General IconGeneral
BrandSICK
ModelIQB2S
CategorySwitch
LanguageEnglish

Related product manuals