If the RSSI value is 0, then no distance measurement is possible. There can be two
reasons for this:
The target object lies outside the sensing range.
The target object has an extremely low remission.
Please note that white paper can have very similar values as a reflector at a short
distance.
The RSSI values are sensor-specific, relative values that can vary slightly between
different devices and during the service life of the device.