5 Mounting
5.1 Scope of delivery
Device in the version ordered (including mounting bracket, if applicable)
Quick start guide
Safety notes
The fibers are not included with delivery.
5.2 Mounting requirements
Typical space requirement for the device, see type-specific dimensional drawing, see "Technical data",
page 71.
Comply with technical data, such as the permitted ambient conditions for operation of the device (e.g.,
temperature range, EMC interference emissions, ground potential),
To prevent condensation, avoid exposing the device to rapid changes in temperature.
Protect the device from direct sunlight.
shock and vibration-free mounting
5.3 Connecting fibers
4
5
6
1
3
2
Figure 4: Connecting fibers
1.
Open the fiber locking mechanism1.
2.
Insert the fibers 4 into the openings provided (see receiver and sender symbol on the housing) 2+5as far
as they will go (check the indicator for correctly inserted fibers 6).
3.
Close the fiber locking mechanism 3.
NOTICE
When using a fiber optic proximity variant with a coaxial fiber arrangement, connect the single-core optical fiber to
the sender. Connect the multi-core optical fiber (fiber bundle) to the receiver.