02.202016/28 H47.ELEKS014EN-00
GENIUS 2.2 PANIC, Electromechanical mul-point lock
The Day / Night switchover mode can be acvated via the buon with menu LED or via the terminal 1. Dierent
pre-sengs can be made. E.g. the buon with menu LED can be deacvated and, in return, an external switch ac-
vated in order to exclude an unauthorised switchover of the Day/Night mode on the GENIUS 2.2 PANIC. The last
status set on the buon remains.
Day operaon is acve when terminal 1 is locked via a potenal-free make contact. Night operaon is acve when
the make contact is open.
The following values can be set in the menu "Day/Night switchover per buon and terminal 1":
LED
Funcon 1
Buon inacve / terminal 1 inacve
Funcon 2
Buon inacve / terminal 1 acve
Funcon 3
Buon acve / terminal 1 inacve
(Funcon 4)
Buon acve / terminal 1 acve:
the mode of operaon can be reset via terminal 1 or via the buon.
Funcon 5
Day mode via terminal 1 acve = single switchover to night mode via buon is possible.
Funcon 6
Night mode via terminal 1 acve = single switchover to day mode and back to night mode via buon is possible.
LED
1
8 s
Magenta Retrieve menu sengs
2 3 x 1 s*
Green Change to menu "Day/Night switchover per buon and terminal 1"
3 3 s
(Example)
Display of the current set values
(Default value: funcon 4)
4 (X) x 1 s
to
Green/
White
Green/
Magenta
Changing the values to the desired value:
Funcon 1 to funcon 6
5 3 s
(Example) Select value, save and exit menu
-
Funcon 1
Funcon 2
Funcon 3
(Funcon 4)
Funcon 5
Funcon 6