02.202024/28 H47.ELEKS014EN-00

GENIUS 2.2 PANIC, Electromechanical mul-point lock
 
We recommend checking the acvaon force required for the release of the GENIUS 2.2 PANIC mul-point lock
with a dynamometer.
To obtain comparable values, the measurements must always be taken at the same locaon of the push bar/lever
handle.
  
Measurement on the lever handle:
measure monthly at the same locaon at the
pressure end.
Measurement on the push bar:
measure monthly at three same locaons.
- on the LH handle
- on the RH handle
- in the middle of the rod
Document the measured values.
The unlocking of the door will be impeded or
prevented if the acvang force is too high. The
acvang force must be designed to ensure that
children and elderly, inrm people are also in a
posion to open the door.
If the measured values deviate considerably from
the determined values of the previous month, this
deviaon can be an indicator of wear and tear.
Get in touch with your contractual partner.
 
  
Check the lubricaon status for:
- contaminaon
- dryness
- resin
If the GENIUS 2.2 PANIC mul-point lock is insuf-
ciently lubricated, contaminated, or hardened
due to an inappropriate lubricant, this will lead to
sluggishness and wear and tear.
This will lead to malfuncon/ failure.
Clean the contaminated areas with a dry cloth.
Lubricate all lubricaon points with a resin-free,
fully synthec spray lubricant (see page 26).
The use of resinous lubricants is inadmissible.
The enre GENIUS 2.2 PANIC mul-point lock
must be replaced if resinous lubricants are
used.
Get in touch with your contractual partner.