EasyManua.ls Logo

Siemens 1FT6031-4AK71-4AH0-Z - Table 1-6 Resistor Braking for the 1 FT6 Series, Force-Ventilated

Siemens 1FT6031-4AK71-4AH0-Z
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor Description
1.6 Armature short-circuit braking
Forced cooling
Table 1-6 Resistor braking for the 1FT6 series, force-ventilated
Average braking torque
M
br rms
[Nm]
rms braking current
I
br rms
[A]
Motor type Braking
resistor
external
R
opt
[Ω]
without
external
braking resistor
with
external
braking resistor
Max.
braking
torque
M
br max
[Nm]
without
external
braking resistor
with
external
braking resistor
SH 80, force ventilated
1FT6084-8SF7 2.3 8.1 18 22 29 26
1FT6084-8SH7 1.7 6.8 18 22 44 39
1FT6084-8SK7 1.4 4.7 18 22 54 48
1FT6086-8SF7 1.6 11 27 34 42 38
1FT6086-8SH7 1.1 7.5 27 34 61 55
1FT6086-8SK7 1.1 6.6 27 34 74 66
SH 100, force ventilated
1FT6105-8SB7 2.0 21 44 55 35 31
1FT6105-8SC7 1.5 17 44 55 47 42
1FT6105-8SF7 1.2 13 44 55 65 58
1FT6105-8SH7 0.9 10 44 55 96 86
1FT6108-8SB7 1.2 33 71 88 58 52
1FT6108-8SC7 0.9 27 71 88 77 69
1FT6108-8SF7 0.6 20 71 88 115 103
SH 132, force ventilated
1FT6132-6SB7 1.2 36
1)
83 105 63 57
1FT6132-6SC7 1.0 30
1)
83 105 83 74
1FT6132-6SF7 0.7 23
1)
83 105 120 110
1FT6134-6SB7 0.9 49
1)
110 140 81 73
1FT6134-6SC7 0.8 40
1)
110 140 105 95
1FT6134-6SF7 0.6 30
1)
110 140 150 140
1FT6136-6SB7 0.8 54
1)
130 170 99 88
1FT6136-6SC7 0.6 43
1)
130 170 130 120
1FT6136-6SF7 0.5 33
1)
130 170 190 170
SH 160, force ventilated
1FT6163-8SB7 0.3
2)
380 490 270
1FT6163-8SD7 0.25
2)
380 490 390
1FT6168-8SB7 0.27
2)
530 680 340
1)
When utilized acc. to M
0
(100 K) a series braking resistor must be used in order to prevent
partial de-magnetization. When utilized according to M
0
(60 K), the additional braking resistor
is not required.
2)
In order to prevent that the motors are de-magnetized, when short-circuit braking from the
rated speed, the above specified supplementary resistors must be connected in series.
1FT6 synchronous motors
1-18 Configuration Manual, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0