3TK2810-1 safety-related speed monitor
System Manual, 01/2011, 926246402000 DS 02
13
Product description
2
2.1 Overview
All key product features at a glance
General information:
TÜV approval / UL approval
Suitable for use in applications to Level (SIL) 3 in accordance with IEC 61508
SIL claim limit (SIL CL) 3 in accordance with IEC 62061
Performance Level (PL) e in accordance with EN ISO 13849-1
in accordance with EN 60204
Width 45 mm
Frequencies from 1Hz to 400 kHz can be monitored depending on the sensor used.
Sensors:
1-channel or 2-channel protective door monitor
Monitoring of a release magnet (spring-locked tumbler)
PNP or NPN initiators adjustable
Connection of different encoders possible (sin/cos, TTL, HTL)
Please note the signal shape in Chapter Technical data (Page 63).
Connec
tion of NAM
UR initiators possible (note device versions)
Outputs:
2 enabling circuits with positively-driven contacts (2-channel configuration)
2 semiconductor signaling outputs
Times:
Adjustable start override (0 to 20 s)
Adjustable release delay time (0 to 600 s)
Adjustable switch-off monitoring (0.5 to 600 s)