SIMATIC ET 200S distributed I/O 2AI U HS analog electronic module (6ES7134-4FB51-0AB0)
_
_____________
_
_____________
_
_____________
_
_____________
_
_____________
Preface
Properties
1
Parameters
2
Diagnostics
3
Analog value representation
4
Connecting
5
SIMATIC
ET 200S distributed I/O
2AI U HS analog electronic module
(6ES7134-4FB51-0AB0)
Manual
04/2007
A5E01076015-01

Questions and Answers

  • C
    claytonrickyAug 12, 2025
    How to fix Siemens 6ES7134-4FB51-0AB0 ET 200S when it does not start up due to a configuration error?
    • A
      Alexa AcevedoAug 12, 2025
      If your Siemens I/O Systems ET 200S fails to start due to a configuration error, it might be caused by multiple power module entries ending in '...O' or '...SO' in the ET 200S configuration. To resolve this, review and correct the configuration within HWCONFIG.
  • J
    Jeffrey BernardAug 18, 2025
    What to do if there is no clocked signal detection/output in Siemens 6ES7134-4FB51-0AB0 I/O Systems?
    • J
      Jamie MooreAug 19, 2025
      If there is no clocked signal detection/output in your Siemens I/O Systems, it might be due to the wrong process image partition being used, resulting in a negative RET_VAL with SFCs 126/127. Verify that the same process image partition is used in the OB 61 user program (or up to OB 64) when SFCs 126/127 are called and in the configuration of the DP master/DP slave.
  • A
    amy86Aug 27, 2025
    Why are the equidistance times too long in Siemens 6ES7134-4FB51-0AB0 I/O Systems?
    • B
      Brandi GardnerAug 27, 2025
      If the equidistance times are too long in your Siemens I/O Systems, it could be that the input delays of the HIGH FEATURE digital input modules are not optimally set. To resolve this, decrease the input delay of the HIGH FEATURE digital input modules.
  • B
    Brandon BennettSep 3, 2025
    How to fix station failure of the Siemens ET 200S I/O Systems?
    • W
      Willie ThomasSep 3, 2025
      Station failure of the Siemens ET 200S I/O Systems can occur due to errored clocking (more than 10 lost or interrupted cycles). To fix this, check the parameter assignment.

Siemens 6ES7134-4FB51-0AB0 Specifications

General IconGeneral
Product Type Designation6ES7134-4FB51-0AB0
Module TypeDigital Input Module
Number of Inputs4
Input Voltage24 V DC
Operating Voltage24 V DC
Protection ClassIP20
Product FamilySIMATIC ET 200SP
Relative Humidity5 to 95% (non-condensing)

Related product manuals