Siemens PM240-2_EN_rev00-30082019.docx 5-3
5.5 TECHNICAL DATA
Table 8 Technical data of braking resistors for PM240-2 Power Modules, frame sizes FSB, FSC
Order number
6SL3201-0BE21-8AA0
6SL3201-0BE23-8AA0
Suitable for Power Modules of
frame size
FSB
FSC
Resistance
Ω
75
30
Unit rating PDB
W
375
925
Peak power Pmax
kW
7.5
18.5
Load duration for peak power Ta
s
Figure 12
Period duration of braking duty
cycle T
s
Figure 12
Degree of protection
IP20
IP20
Power connections (including PE)
4 mm2 / 0.7 Nm
10 AWG / 6.2 lbf in
4 mm2 / 0.7 Nm
10 AWG / 6.2 lbf in
Weight
kg
2.7
6.2
Table 9 Technical data of braking resistors for PM240-2 Power Modules, frame sizes FSD to FSF
Order number
JJY023422620001
JJY:023434020001
JJY023454020001
JJY023424020001
JJY023464020001
Suitable for Power Modules of frame size
FSD
FSE
FSF
Resistance
Ω
25 con In ≤ 45A
10
7.1
15 con In > 45A
5
Unit rating PDB
W
1100
2750
3850
1850
5500
Peak power Pmax
kW
22
55
77
37
110
Load duration for peak power Ta
s
Figure 12
Period duration of braking duty cycle T
s
Figure 12
Figure 12
Figure 12
Degree of protection
IP21
IP21
IP21
Power connections (including PE)
10 mm2 / 0.8 Nm
8 AWG / 7.1 lbf in
16 mm2 / 1.2 Nm
6 AWG / 4.5 lbf in
10 mm2 / 0.8 Nm
8 AWG / 7.1 lbf in
10 mm2 / 0.8 Nm
8 AWG / 7.1 lbf in
16 mm2 / 1.2 Nm
6 AWG / 4.5 lbf in
Weight
kg
7.0
13.5
7
9.5
13.5
Duty cycles
Figure 12 Load diagram for the braking resistor, in Blocksize format
T [s] period duration of braking duty cycle
Ta [s] load duration for peak power
PDB [W] unit rating of the braking resistor
Pmax [W] peak braking power of the braking resistor

Table of Contents