Article number 6ES7512-1DM03-0AB0
•
RS 485 Yes; Via CM DP module
•
Number of ports 1
Protocols
•
PROFIBUS DP master Yes
•
PROFIBUS DP slave Yes
•
SIMATIC communication Yes
PROFIBUS DP master
•
Number of connections, max. 48; Of which 4 each reserved for ES and HMI
•
Number of DP slaves, max. 125; In total, up to 512 distributed I/O devices
can be connected via AS-i, PROFIBUS or PROFINET
Services
–
PG/OP communication Yes
–
Equidistance No
–
Isochronous mode No
–
Activation/deactivation of DP slaves Yes
Interface types
RJ 45 (Ethernet)
•
100 Mbps Yes
•
Autonegotiation Yes
•
Autocrossing Yes
•
Industrial Ethernet status LED Yes
RS 485
•
Transmission rate, max. 12Mbit/s
Protocols
PROFIsafe No
Number of connections
•
Number of connections, max. 128; via integrated interfaces of the CPU and con
nected CPs / CMs
•
Number of connections reserved for
ES/HMI/web
10
•
Number of connections via integrated
interfaces
88
•
Number of connections per CP/CM 32
•
Number of S7 routing paths 16
Redundancy mode
•
H-Sync forwarding Yes
Media redundancy
–
Media redundancy Yes; only via BusAdapter
–
MRP Yes; MRP Automanager according to IEC 62439-2
Edition 2.0, MRP Manager; MRP Client
34
CPU 1512SP-1 PN (6ES7512-1DM03-0AB0)
Equipment Manual, 11/2022, A5E33591411-AE
Technical specifications