CPU 31xC and CPU 31x, Technical Data
Manual, 01/2006 Edition, A5E00105475-06
xi
6.5 CPU 314C-2 PtP and CPU 314C-2 DP ................................................................................... 6-21
6.6 Technical data of the integrated I/O......................................................................................... 6-28
6.6.1 Arrangement and usage of integrated I/Os.............................................................................. 6-28
6.6.2 Analog I/O ................................................................................................................................ 6-34
6.6.3 Parameterization...................................................................................................................... 6-38
6.6.4 Interrupts.................................................................................................................................. 6-43
6.6.5 Diagnostics............................................................................................................................... 6-44
6.6.6 Digital inputs............................................................................................................................. 6-45
6.6.7 Digital outputs .......................................................................................................................... 6-47
6.6.8 Analog inputs ........................................................................................................................... 6-49
6.6.9 Analog outputs ......................................................................................................................... 6-51
7 Technical data of CPU 31x ..................................................................................................................... 7-1
7.1 General technical data ............................................................................................................... 7-1
7.1.1 Dimensions of CPU 31x............................................................................................................. 7-1
7.1.2 Technical specifications of the SIMATIC Micro Memory Card (MMC) ...................................... 7-2
7.2 CPU 312..................................................................................................................................... 7-3
7.3 CPU 314..................................................................................................................................... 7-8
7.4 CPU 315-2 DP ......................................................................................................................... 7-13
7.5 CPU 315-2 PN/DP ................................................................................................................... 7-19
7.6 CPU 317-2 DP ......................................................................................................................... 7-26
7.7 CPU 317-2 PN/DP ................................................................................................................... 7-33
7.8 CPU 319-3 PN/DP ................................................................................................................... 7-40
A Appendix.................................................................................................................................................A-1
A.1 Information about upgrading to a CPU 31xC or CPU 31x .........................................................A-1
A.1.1 Scope .........................................................................................................................................A-1
A.1.2 Changed behavior of certain SFCs............................................................................................A-2
A.1.3 Interrupt events from distributed I/Os while the CPU status is in STOP ...................................A-4
A.1.4 Runtimes that change while the program is running ................................................................. A-4
A.1.5 Converting the diagnostic addresses of DP slaves ................................................................... A-5
A.1.6 Reusing existing hardware configurations.................
................................................................A-5
A.1.7 Replacing a CPU 31xC/31x .......................................................................................................A-6
A.1.8 Using consistent data areas in the process image of a DP slave system ................................. A-6
A.1.9 Load memory concept for the CPU 31xC/31x ...........................................................................A-7
A.1.10 PG/OP functions ........................................................................................................................A-7
A.1.11 Routing for the CPU 31xC/31x as an intelligent slave...............................................................A-7
A.1.12 Changed retentive behavior for CPUs with firmware >= V2.1.0 ................................................A-8
A.1.13 FMs/CPs with separate MPI address in the central rack of a CPU 315-2 PN/DP,
a CPU 317 or a CPU 319-3 PN/DP ...........................................................................................A-8
A.1.14 Using loadable blocks for S7 communication for the integrated PROFINET interface .............A-9
Glossary ..................................................................................................................................... Glossary-1
Index................................................................................................................................................ Index-1

Table of Contents

Other manuals for Siemens CPU 313C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 313C and is the answer not in the manual?

Siemens CPU 313C Specifications

General IconGeneral
MPI InterfaceYes
Number of digital inputs24
Number of digital outputs16
Number of analog inputs4
Number of analog outputs2
Supply voltage24 V DC
High-speed countersYes
Bit Operations Execution Time0.1 µs
Word Operations Execution Time0.2 µs
Power Consumption5 W
Dimensions (W x H x D)40 x 125 x 130 mm
Operating Temperature0 to 60 °C
Communication InterfacesMPI
Programming LanguagesLAD, FBD, STL
Product type designationCPU 313C
Weight490 g