EasyManuals Logo

Siemens CPU 313C User Manual

Siemens CPU 313C
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
Memory concept
4.1 Memory areas and retentivity
CPU 31xC and CPU 31x, Technical Data
4-4 Manual, 01/2006 Edition, A5E00105475-06
Retentive behavior of a DB for CPUs with firmware >= V2.1.0
For these CPUs you can specify in STEP 7 (beginning with version 5.2 + SP 1), or at
SFC 82 CREA_DBL (parameter ATTRIB -> NON_RETAIN bit), whether a DB at POWER
ON/OFF or RUN-STOP
keeps the actual values (retentive DB), or
accepts the initial values from load memory (non-retentive DB)
Table 4-3 Retentive behavior of DBs for CPUs with firmware >= V2.1.0
At POWER ON/OFF or restart (warm start) of the CPU, the DB should
receive the initial values
(non-retentive DB)
retain the actual values (retentive DB)
Reason:
At POWER ON/OFF and restart (STOP-
RUN) of the CPU, the actual values of the
DB are non-retentive. The DB receives the
start values from load memory.
Reason:
At POWER OFF/ON and restart (STOP-RUN) of the
CPU, the actual values of the DB are retained.
Requirement in STEP 7:
The "Non-retain" check box must be set
in the block properties of the DB, or
a non-retentive DB was generated with
SFC 82 "CREA_DBL" and the
corresponding block attribute (ATTRIB -
> NON_RETAIN bit.)
Requirement in STEP 7:
The "Non-retain" check box must be reset in the
block properties of the DB or
a retentive DB was generated with SFC 82.
Note
Note:
Only 256 KB of RAM can be used for retentive DBs on a CPU 317.
Only 700 KB of RAM can be used for retentive DBs on a CPU 319.
The remainder of the RAM is used by code blocks and non-retentive data blocks.
4.1.4 Address areas of system memory
The system memory of the S7 CPUs is organized in address areas (refer to the table below).
In a corresponding operation of your user program, you address data directly in the relevant
address area.

Table of Contents

Other manuals for Siemens CPU 313C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 313C and is the answer not in the manual?

Siemens CPU 313C Specifications

General IconGeneral
MPI InterfaceYes
Number of digital inputs24
Number of digital outputs16
Number of analog inputs4
Number of analog outputs2
Supply voltage24 V DC
High-speed countersYes
Bit Operations Execution Time0.1 µs
Word Operations Execution Time0.2 µs
Power Consumption5 W
Dimensions (W x H x D)40 x 125 x 130 mm
Operating Temperature0 to 60 °C
Communication InterfacesMPI
Programming LanguagesLAD, FBD, STL
Product type designationCPU 313C
Weight490 g

Related product manuals