Technical data of CPU 31xC
6.6 Technical data of the integrated I/O
CPU 31xC and CPU 31x, Technical Data
Manual, 01/2006 Edition, A5E00105475-06
6-53
Technical data
Voltage output
Short-circuit protection
Yes
Short-circuit current
Typically 55 mA
Current output
No-load voltage
Typically 17 V
Destruction limit for externally applied voltages/currents
Voltage measured between the outputs and M
ANA
Max. 16 V
Current
Max. 50 mA;
Connection of actuators
For voltage outputs
wire connection
wire connection (test lead)
Possible, without compensation of
cable resistance
Not possible
For current outputs
wire connection
Possible

Table of Contents

Other manuals for Siemens CPU 313C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 313C and is the answer not in the manual?

Siemens CPU 313C Specifications

General IconGeneral
MPI InterfaceYes
Number of digital inputs24
Number of digital outputs16
Number of analog inputs4
Number of analog outputs2
Supply voltage24 V DC
High-speed countersYes
Bit Operations Execution Time0.1 µs
Word Operations Execution Time0.2 µs
Power Consumption5 W
Dimensions (W x H x D)40 x 125 x 130 mm
Operating Temperature0 to 60 °C
Communication InterfacesMPI
Programming LanguagesLAD, FBD, STL
Product type designationCPU 313C
Weight490 g