EasyManua.ls Logo

Siemens EH675TK11E - Pot Detection for Flexinduction Models

Siemens EH675TK11E
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
206_58300000141095_ara_en_k.doc – 04.10.a Seite 106 von 113
5.24 Pot detection for FlexInduction models
Warning!
If the pan is not detected correctly, it is necessary to verify the pan
situation respect to the NTC of the oval inductor.
The aesthethic help us to know where we must place the pots.
5.24.1 Pot detection
The recommendation to obtain a good pot regulation is as follows:
o For pot diameters minors of 130 mm ,we must place
them centered in the middle of the oval inductor. The
aesthethic help us to know where we must place the
pots.
o For pot diameters major of 130 mm, we must place them
between two oval zones, with both NTC covered.
If we don´t follow these recommendations, the pot can not be
detected in some ocasions
when it is off-centered, it would not be detected for security
5.24.2 Flexible zones aesthetics
5.24.2.1 For Bosch models

Related product manuals