EasyManua.ls Logo

Siemens ET 200S - Page 158

Siemens ET 200S
564 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning and Diagnostics
6-34
Distributed I/O System ET 200S
EWA 4NEB 780 6024-02 07
6.6.6 Module Diagnosis
Definition
The module diagnosis indicates whether or not modules of the ET 200S have
errors/faults. The module diagnosis begins as of byte 6 and comprises:
3 bytes in the case of the IM151-1 BASIC
9 bytes in the case of the IM151-1 STANDARD, IM151-1 FO STANDARD, and
IM151-1 HIGH FEATURE.
Module Diagnosis
The module diagnosis for the ET 200S with the IM151-1 BASIC is structured as
follows:
Byte 6
Bit no.
Byte 7
Byte 8
713654
2
0
Module: 1 to 8
Module: 9 to 12
7
1365
42
8
1112 10 9
Events on the correspon-
ding module are indica-
ted by set bits.
70
Bit no.
Length of the module diagnosis
including byte 6 (= 3 bytes)
Code for module diagnosis
01
65
110000
****
* Always 0
Figure 6-21 Structure of the Module Diagnosis for the ET 200S with the IM151-1 BASIC