EasyManuals Logo

Siemens LMV27.100x2 User Manual

Siemens LMV27.100x2
219 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
4/219
Building Technologies Basic Documentation LMV27... CC1P7541en
17.12.201816
7.3 Digital input .................................................................................................... 36
7.3.1 Safety loop X3–04, pin 1 and 2 ...................................................................... 36
7.3.2 Burner flange X3–03, pin 1 and 2 .................................................................. 37
7.3.3 Input for external load controller (ON / OFF) X5–03, pin 1 ............................ 37
7.3.4 Inputs X5–03 pin 2 and 3 (Opening / Closing or stage 2 / stage 3) ............... 37
7.3.5 Air pressure switch X3–02 ............................................................................. 38
7.3.6 Gas pressure switch for valve proving X9-04 ................................................ 39
7.3.7 Gas / oil pressure switch-min, start release gas X5-01 .................................. 40
7.3.8 Setting the time for making the pressure switch test ..................................... 42
7.3.9 Gas / oil pressure switch-max / oil pressure-max or POC contact, start
release oil X5–02 ........................................................................................... 43
7.3.10 Reset X8-04, pin 1 ......................................................................................... 44
7.4 Digital outputs ................................................................................................ 45
7.4.1 Output alarm type No-SI – X3–05, pin 2 ........................................................ 45
7.4.2 Fan motor contactor type SI – X3–05, pin 1 .................................................. 45
7.4.3 Continuous fan operation – X3–05, pin 3 ....................................................... 45
7.4.4 Output ignition type SI (IGNITION) – X4–02 .................................................. 46
7.4.5 Outputs fuel valves V1 / V2 / V3 / PV, type SI – X8–02, X7-01, X7-02 .......... 47
7.4.6 Output safety valve type SI – X6–03 .............................................................. 47
7.4.7 Output for indication of operation X8-04, pin 2 .............................................. 47
7.5 Program sequence ......................................................................................... 48
7.5.1 Time parameters ............................................................................................ 48
7.5.2 Valve proving ................................................................................................. 49
7.5.2.1. Valve proving with separate pressure switch X9-04 ...................................... 50
7.5.2.2. Valve proving via gas pressure switch-min X5-01 ......................................... 51
7.5.2.3. Lockout phase (phase 00) ............................................................................. 51
7.5.2.4. Safety phase (phase 01) ................................................................................ 52
7.5.3 Special functions during the program sequence ............................................ 53
7.5.3.1. Reset / manual lockout .................................................................................. 53
7.5.3.2. Alarm upon start prevention ........................................................................... 54
7.5.3.3. Possible start preventions .............................................................................. 54
7.5.3.4. Repetition counter .......................................................................................... 55
7.5.3.5. Start without prepurging (as per EN 676) ...................................................... 57
7.5.3.6. Gas shortage program ................................................................................... 58
7.5.3.7. Program stop function .................................................................................... 59
7.5.3.8. Forced intermittent operation (<24 hours) ..................................................... 59
7.5.3.9. Low-fire shutdown .......................................................................................... 59
7.5.3.10. Continuous fan ............................................................................................... 60
7.5.3.11. Test function for approval of burner – loss-of-flame test (TÜV test) .............. 61
7.5.3.12. Postpurging in the lockout position ................................................................ 62
7.6 Fuel trains (application examples) ................................................................. 63
7.7 Sequence diagrams ....................................................................................... 71
7.7.1 Gas direct ignition «G», «G mod», «G mod pneu» ........................................ 71
7.7.2 Gas pilot ignition 1 «Gp1», «Gp1 mod», «Gp1 mod pneu» ........................... 72
7.7.3 Gas pilot ignition 2 «Gp2», «Gp2 mod», «Gp2 mod pneu» ........................... 73
7.7.4 Light oil direct ignition «Lo», «Lo mod», «Lo 2 stage», « Lo 3-stage» ........... 74
7.7.5 Light oil – pilot ignition «LoGp»«LoGp mod» «LoGp 2-stage» ...................... 75
7.7.6 Legend to the sequence diagrams ................................................................. 76
8 Selection of operating mode ....................................................................... 79

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens LMV27.100x2 and is the answer not in the manual?

Siemens LMV27.100x2 Specifications

General IconGeneral
BrandSiemens
ModelLMV27.100x2
CategoryController
LanguageEnglish

Related product manuals