Panel Present X7
Connector designa‐
tion:
X7
Connector type: 6-pin Phoenix terminal
Table 3-17 Assignment of the interface Panel Present X7
Pin Signal name Signal type Meaning
1 PRES O "High": Panel (HT 8) plugged in
2 N.C. - Not assigned
3 N.C. - Not assigned
4 N.C. - Not assigned
5 N.C. - Not assigned
6 M P Ground
Emergency stop wiring terminal X8
Connector designa‐
tion:
X8
Connector type: 4-pin Phoenix terminal
Table 3-18 Assignment of the emergency stop wiring terminal X8
Pin Connection
1 On-board jumper between 1 and 2
2
3 On-board jumper between 3 and 4
4
Note
Use this terminal for simple routing of the emergency stop cables, optional.
The connector is only used to assist looping through. The connected pins 1 and 2 as well as 3 and
4 have no additional function on the connection module.
Enabling X20
Connector designa‐
tion:
X20
Connector type: MCV 1.5/8-G3.81
Cable length (max.): 30 m
Description
3.4 Interfaces
Machine Pushbutton Panel: MPP 464 IE H
30 Equipment Manual, 03/2021, A5E50810237B AA