Do you have a question about the Siemens MODULARIS Uro Plus and is the answer not in the manual?
X-ray Generator | High-frequency generator |
---|---|
Tube Voltage Range | 40 - 125 kV |
Manufacturer | Siemens |
Application | Urology |
Focal Spot Size | 0.6 / 1.0 mm |
Imaging Technology | Digital Fluoroscopy |
Flat Panel Detector Option | Yes |
Angulation Range | ± 180° |
Table Load Capacity | Up to 200 kg |
Table Movements | Motorized longitudinal, lateral, height adjustment |
Image Processing | Real-time digital image processing |
Monitor | High-resolution LCD monitors |
Footswitch | Yes |
Laser Positioning | Yes |
Compatibility | DICOM |
Adheres to safety measures and points to observe during operations.
Covers leakage current measurement and local/national regulations.
Details initial leakage current measurement performed at the factory.
Explains when and how to repeat leakage current tests after service.
Lists required tools and measurement devices for service.
Lists required auxiliary devices and related service instructions.
Details system power on/off messages and their causes/actions.
Lists errors related to the cooling system, water level, and pressure.
Details errors for water level and coupling pressure, with causes and actions.
Describes errors related to control unit contact and X-ray button.
Lists errors for ECG signal, C-arm movement, and potentiometer.
Details errors for ECG option, control unit, C-arm direction, and button issues.
Covers errors related to temperature sensors and ADC access.
Details errors for cooling pump, power supply, and valves.
Covers errors for potentiometer, power supply, and battery.
Lists errors related to charging current, overvoltage, and overtemperature.
Details errors for charging current, spark gap ignition, and constancy limit.
Covers chip card errors, charging process time, and HV cable issues.
Lists errors related to flash memory, pulse counters, and watchdog.
Details errors for ultrasound connection, potentiometers, and US values.
Explains board D3 displays and console messages like 'Chip card invalid'.
Describes using Hyper Terminal to retrieve error codes, settings, and therapy data.
Step-by-step guide for connecting via Hyper Terminal on German Windows.
Step-by-step guide for connecting via Hyper Terminal on English Windows.
Explains how to interpret output from the terminal program, including compatibility checks.
Details commands to display help, pulse counters, and diagnostic data.
Explains how to view and delete the error log using the terminal program.
Describes how to display and manage therapy data by date.
Details how to view card data, including sequential and serial numbers.
Covers adjusting C-arm time, installing ECG trigger, and ultrasound adjustment.
Explains how to set pulse rate and perform software downloads.
Step-by-step guide for downloading software using Windows.
Details how to change the treatment table orientation.
Explains text displayed after replacing board D3 and system name definition.
Lists system parts, item numbers, and comments on their replacement.
Procedure for removing and reattaching shock wave head covers.
Step-by-step guide for removing the shock wave head.
Procedure for installing a new shock wave head.
Instructions for installing coupling bellows and replacing hose pump heads.
Procedure for replacing the iso-center phantom.
Steps to check the cooling unit's function and connections.
Procedures for replacing the cooling unit and filling circuits.
Procedure to empty the cooling circuit using the old pump.
Procedure to empty the cooling circuit using the new pump.
Instructions for removing and installing hose pump heads in coupling and cooling circuits.
Steps for removing and installing the IWAKI cooling pump.
Procedure for replacing the charging unit and performing post-replacement checks.
Steps for removing and connecting the high voltage connector.
Procedure for replacing cables within the corrugated tubing.
Procedure for replacing the air suction hose for serial number 0050.
Procedure for replacing the air suction hose for serial number 0051.
Notice for Gold card usage and procedure for replacing board D3.
Instructions for adjusting potentiometer for ultrasound addition.
Procedure for performing pressure measurements on the shock wave system.
Steps for replacing and adjusting the potentiometer for the angulation drive.
Procedure for replacing the angulation drive (C-arm drive).
Procedure for SIREMOBIL Iso-C switch and removing/re-attaching the docking plate.
Steps for removing and replacing switches on the SIREMOBIL.
Procedure for adjusting switches S1/S2 and their function.
Procedure for setting the cam on the LITHOSTAR MODULARIS.
Procedure for replacing the balancing spring for the support arm.
Step-by-step guide for replacing the support arm, including notes on assistance.
Procedure for removing and replacing the rotary joint lock.
Steps for replacing the sector probe, including sleeve attachment.
Procedure for replacing the curved probe, including sleeve attachment.
Final steps including protective conductor measurement and function tests.
Outlines the iso-center adjustment steps for I.I., X-ray tube, and shock wave head.
Detailed steps for adjusting the iso-center to the 0° position.
Detailed steps for adjusting the iso-center to the 20° positions.
Final steps for iso-center alignment, including measurements and checks.
Outlines iso-center adjustment for serial number 0051, comparing to 0050.
Steps for adjusting the 0° iso-center position for serial 0051.
Steps for adjusting the 20° iso-center position for serial 0051.
Final steps for serial 0051 iso-center alignment, including measurements and checks.
Explains LithoShare for coupling multiple SIREMOBIL Iso-C units with one LITHOSTAR.
Details iso-center and potentiometer adjustment procedures for LithoShare systems.
Steps to fit the probe holder and connect probes for ultrasound localization.
Procedure for checking the target on the Sonoline G20 ultrasound system.
Procedure to check and adjust image tilt using the isocenter phantom.
Procedure to check distance in height using measurement keys and trackball.
Procedure to check distance side-to-side using measurement keys and trackball.
Procedure for checking the target on the Sonoline Adara ultrasound system.
Procedure to check and adjust image tilt using the isocenter phantom.
Procedure to check height distance on Sonoline Prima.
Procedure to check side distance on Sonoline Prima.
Procedure for checking the target on the Sonoline Prima ultrasound system.
Procedure to check and adjust image tilt using the isocenter phantom.
Procedure to check height distance on ultrasound arm.
Procedure to check side distance on ultrasound arm.
Details organ program parameters for SIREMOBIL Iso-C with LITHOSTAR MODULARIS.
Procedure for selecting MODULARIS cross on SONOLINE G20 for ultrasound localization.
Procedure for selecting MODULARIS cross on SONOLINE Adara for ultrasound localization.
Procedure for selecting MODULARIS cross on SONOLINE Prima for ultrasound localization.
Instructions for labeling the ultrasound unit and MUT MODULARIS startup.
Details functions like Litho Mode, Target Sector, and Image Tilt.
Lists communication settings like Baud-Rate, Data Length, Parity, and Stop bit.
Instructions to read software versions on different ultrasound devices.
Details changes made to the cover sheet, revision status, and table of contents.
Details changes to stopbit settings for German and English Windows connections.