Plug X25
Connector designation: X25
Connector type: MCD 1.5/8-G1-3.81 HT BK
Cable length (max.): 1.5 m
Table 3-15 Plug X25
Pin Signal Type Signal name Pin Signal Type Signal name
B1 P24_OUT V Reference pot. +24 V A1 M24_EXT V Reference pot. +24 V
B2 S13 I Emergency stop button A2 HS13 O Emergency stop LED
B3 S14 KT-S14 A3 HS14 LED-S14
B4 S15 KT-S15 A4 HS15 LED-S15
B5 S59 *) KT-IN3/emergency stop override A5 H59 LED-S59
B6 S60 Mode selection A6 H60 LED-S60
B7 S61 Rapid withdrawal A7 H61 LED-S61
B8 S62 *) S32 / HGA enabling unit plug‐
ged in / terminating connector
A8 M24_EXT Reference pot. +24 V
*) can only be used as a neutral input without HGA
Connection for handheld units
You will 󹪝nd a detailed drawing showing the locations of the interfaces in section "Device rear".
Ethernet X1 / X2
Connector designation: X1, X2
Connector type: RJ45 socket
Table 3-16 Ethernet X1 / X2
Pin Signal name Type Meaning
1 TD+
O
Send data +
2 TD- Send data -
3 RD+ I Receive data +
4 N.C. - Not assigned
5 N.C. - Not assigned
6 RD- I Receive data -
7 N.C. - Not assigned
8 N.C. - Not assigned
Note