Table 3-62: Input Harmonics Menu (8140)
3.3.9 Communications Menu (9) Options
The Communications Menu (9) consists of the following menu options:
Serial Port Setup Menu (9010)
Network Control (9943)
Network 1 Configure (9900)
Network 2 Configure (9914)
Serial Functions (9110)
TCP/IP Setup (9300)
These menu items are explained in tables that follow.
Parameter ID Units Default Min Max Description
Selection for HA 8150 IA
Selection for Harmonic Analysis
•IA
•IB
•IC
•VA
•VB
•VC
Harmonics order 8160 1.0 0.0 30.0 Harmonic Order
Harmonics integral
gain
8170 0.001 0.0 1.0 Harmonics regulator integral gain term