EasyManua.ls Logo

Siemens RUGGEDCOM RS910 - Chapter 4 Technical Specifications; Power Supply Specifications; Failsafe Relay Specifications

Siemens RUGGEDCOM RS910
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RUGGEDCOM RS910
Installation Guide
Chapter 4
Technical Specifications
Power Supply Specifications 21
Technical Specifications
This section provides important technical specifications related to the device.
CONTENTS
Section4.1, “Power Supply Specifications”
Section4.2, “Failsafe Relay Specifications”
Section4.3, “Copper Ethernet Port Specifications”
Section4.4, “Fiber Optic Ethernet Port Specifications”
Section4.5, “Serial Port Specifications”
Section4.6, “Operating Environment”
Section4.7, “Mechanical Specifications”
Section4.1
Power Supply Specifications
Input Range
Power Supply Type
Minimum Maximum
Internal
Fuse Rating
a
Isolation
Maximum Power
Consumption
b
88 VDC 300 VDC 4 kVAC
HI
85 VAC 264 VAC 5.5 kVDC
24 10 VDC 36 VDC 1.5 kVDC
48 37 VDC 72 VDC
3.15 A(T)
1.5 kVDC
10 W
a
(T) denotes time-delay fuse.
b
Power consumption varies based on configuration.
Section4.2
Failsafe Relay Specifications
Maximum Switching Voltage Rated Switching Current Isolation
30 VDC 2 A, 60 W
125 VDC 0.24 A, 30 W
125 VAC 0.5 A, 62.5 W
220 VDC 0.24 A, 60 W
250 VAC 0.25 A, 62.5 W
1500 V
rms
for 1 minute

Other manuals for Siemens RUGGEDCOM RS910

Related product manuals