Chapter 4
Technical Specifications
RUGGEDCOM RS910
Installation Guide
24 Serial Port Specifications
Section4.5
Serial Port Specifications
This section details specifications for ports that can be equipped on the RS910.
CONTENTS
Section4.5.1, “Copper Serial Port Specifications”
Section4.5.2, “Fiber Serial Port Specifications”
Section4.5.1
Copper Serial Port Specifications
Baud Rate Connector Isolation
300 to 230 kbps DB9 or RJ45 2.5 kV
Section4.5.2
Fiber Serial Port Specifications
Mode Connector Typical Distance (km)
Optical
Wavelength (nm)
Cable Size
50/125Multimode ST 5 850
62.5/125
Section4.6
Operating Environment
Parameter Range Comments
Ambient Operating Temperature -40 to 85 °C
(-40 to 185 °F)
Measured from a 30 cm (12 in) radius surrounding the center of the
enclosure.
Ambient Relative Humidity 5% to 95% Non-condensing
Ambient Storage Temperature -40 to 85 °C
(-40 to 185 °F)