Connecting
4.3 Connecting components
SIMATIC TOP connect for S7-1500 and ET200MP
30 Manual,
6. With push-in terminal: Insert the wire fitted with end sleeve into the duct.
7. When using a round-sheath ribbon cable:
Twist down each connecting cable by 90° and give it one turn.
8. Insert the strain relief (cable tie) provided for the cabling into the front connector module.
The strain relief holds the cabling (supply voltage cables and connecting cables) in the
cable storage space of the I/O module.
Figure 4-7 Fitted strain relief (example)
9. Run the connecting cables and the cables for the I/O module supply voltage down and
out of the I/O module.
See also
Wiring rules (Page 21)