Connecting SCALANCE S615 to the WAN
1.7 Setting the time
SCALANCE S615 Getting Started
Getting Started, 03/2015, C79000-G8900-C390-01
21
3. In "NTP Server IP Address", enter the IP address 192.168.100.87. It is not possible to
enter the NTP address as a host name.
4. If necessary, change the port in "NTP Server Port". As default, 123 is set.
5. In "Poll Interval (s)", enter the interval for synchronization. As default, 64 is set.
6. Select NTP Client".
7. Click "Set Values".
Result
System time using NTP is set. Click "Refresh" to refresh the WBM page.