Configuration Using Web Based Management and the Command Line Interface
Syntax of the Command Line
113
Interface
CLI\SYSTE
Comment
M\IP>
Command Description
dhcp [E|D]
Enable / disable DHCP server.
dhcptype [M|N|C]
Specifies how a device will be
M MAC address
C Client ID
identified:
N Device name
clientid
Specifies a client-ID for the device.
ip [IP addre
P
is automatically disabled.
ss]
Specifies the IP address for the
SCALANCE W78x.
When you enter a valid IP
address, enabled DHC
subnet [subnet mask]
Specifies the subnet mask.
gateway [IP address]
Specifies the IP address of the
router.
ttl [TTL value]
Sets the TTL (Time To Live)
parameter.
Default value: 64