Configuration Using Web Based Management and the Command Line Interface
6.7.4 Link Check Menu Command
220
Note
This function is not available in iPCF mode.
Device-Related Connection Monitoring
8x. This service
can be compared with the link on a wired connection. The function monitors
e is available over the wireless medium. If no packet is received
lly after half of the configured monitoring time, the
SCALANCE W78x attempts to send a test packet to the node.
The Link Check function provides device-related connection monitoring for a
maximum of ten wireless nodes logged on at the SCALANCE W7
whether the nod
from the node or sent successfu
Note
With the Link Check function, you can only monitor connections to WLAN clients;
use along with redundancy or WDS is not possible.
System Ev
x reacts to a connection abort (or to the
stem > Events menu.
ent for Connection Abort
You can specify how the SCALANCE W78
reestablishment of a connection) in the Sy
Operating Instructions SCALANCE W78x