Configuration Using Web Based Management and the Command Line Interface
C79000-G8976-C184-07
196
Spanning T e
Port-Specific Parameters
This ither using
the automatic function of the SCALANCE W or by the user.
re Port Settings
page displays the current port parameters. The settings are made e
The eight columns of the port table show the following information:
Port
Specifies the ports to which the information relates. Wireless 1_2, for
example, relates to the virtual access point VAP2 on the first WLAN
interface.
Priority
With this parameter, you specify the priority of the ports of a bridge.
If the path calculated by spanning tree is possible over several ports of a
station, the port with the highest priority (in other words the lowest value for
this parameter) is selected. A value from 0 through 255 can be specified for
the priority; the default is 128.