Connecting up
4.1 Safety when connecting up
SCALANCE XM-400
46 Operating Instructions, 05/2014, C79000-G8976-C306-03
Safety notices when using the device according to ATEX
If you use the device under ATEX conditions you must also keep to the following safety
notices in addition to the general safety notices for protection against explosion:
WARNING
Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
This is the case if you only operate devices with SELV (safety extra-low voltage).
Further notes
WARNING
Commissioning devices and replacement devices
If you use redundancy mechanisms (HRP/MRP ring redundancy and/or redundant coupling
of rings with standby), open the redundant path before you insert a new or replacement
device in an operational network. A bad configuration or attachment of the Ethernet cables
to incorrectly configured ports causes overload in the network and a breakdown in
communication.
A device may only be inserted in a network and connected in the following situations:
With HRP/MRP:
Ring redundancy must be activated
The mode must be selected correctly.
The ring ports of the device being inserted in the HRP/MRP ring must be configured
as ring ports.
With standby link:
The standby connection must be activated.
The "Standby Connection Name" must match the name of the partner device.
The port must be configured as a standby port.
For further information, refer to the configuration manuals (Page 3).
In areas subject to the NEC or CEC:
WARNING
Safety notice for connectors with LAN (Local Area Network) marking
A LAN or LAN segment, with all its associated interconnected equipment, shall be entirely
contained within a single low-voltage power distribution and within a single building. The
LAN is considered to be in an "environment A" according to IEEE802.3 or "environment 0"
according to IEC TR 62102, respectively. Never connect directly to TNV-
circuits (Telephone
Network) or WAN (Wide Area Network).