3 Engineering VRRP
VRRP
Entry-ID: 109798556, V1.0, 09/2021
19
© Siemens AG
2021 All rights reserved
Assigning the IP address
The first assignment of an IP address for the SCALANCE cannot be done with
Web Based Management, because this configuration tool requires an IP address in
the first place.
There are several ways to assign an IP address to an unconfigured device:
SINEC PNI
PRONETA
STEP 7
DHCP
SINEC PNI and PRONETA are available to you for free as downloads in the
Industry Online Support.
Assign the planned IP address to the two SCALANCE routers with one of the
aforementioned tools:
Table 3-2
Device
Function
IP address
Subnet mask
SCALANCE XM408-8C
VRRP master
192.168.1.2
255.255.255.0
SCALANCE XM408-8C
VRRP backup
192.168.1.3
255.255.255.0
Note
VRRPv3 supports IPv4 and IPv6. Both can be configured and operated
simultaneously with VRRPv3.
The following figures describe configuration with SINEC PNI.
1. Click "Start network scan".
2. Select the device found.
3. Click the "Device Management" button.

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals