Technical Specifications
5.5Fiber Optic Ethernet Port Specifications
Tx (dBm)Mode Connector
Type
Cable
Type (µm)
Tx λ
(nm)
a
Minimum Maximum
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
b
Power
Budget
(dB)
SM LC 9/125 1310 0 5 -37 0 90 37
a
Typical.
b
Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a
Siemens sales associates when determining maximum distances.
Gigabit Ethernet (1 Gbps) Optical Specifications
Note
These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20
to 85 °C (-4 to 185 °F) operation only.
Tx (dBm)
c
Mode Connector
Type
Cable
Type
(µm)
a
Tx λ
(nm)
b
Minimum Maximum
Rx
Sensitivity
(dBm)
c
Rx
Saturation
(dBm)
c
Distance
(km)
d
Power
Budget
(dB)
MM LC 50/125 850 -9 -2.5 -20 0 0.5 11
MM LC 62.5/125 850 -9 -2.5 -20 0 0.5 11
SM SC 9/125 1310 -10 -3 -20 -3 10 10
SM LC 9/125 1310 -9.5 -3 -21 -3 10 11.5
SM SC 9/125 1310 -5 0 -20 -3 25 15
SM LC 9/125 1310 -7 -3 -24 -3 25 17
a
All cabling is duplex type unless specified otherwise.
b
Typical.
c
All optical power numbers are listed as dBm averages.
d
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a
Siemens sales associates when determining maximum segment distances.
GBIC Gigabit (1 Gbps) Transceiver Specifications
Note
GBIC transceivers have a temperature range of -40 to 85 °C (-40 to 185 °F), unless
specified otherwise.
Tx (dBm)
c
Mode Connector
Type
Cable
Type
(µm)
a
Tx λ
(nm)
b
Minimum Maximum
Rx
Sensitivity
(dBm)
c
Rx
Saturation
(dBm)
c
Distance
(km)
d
Power
Budget
(dB)
SM SC 9/125 1310 -9.5 -3 -21 -3 10 11.5
SM SC 9/125 1310 -7 -3 -24 -3 25 17
SM
e
SC 9/125 1550 0 5 -23 -3 70 23
a
All cabling is duplex type unless specified otherwise.
b
Typical.
c
All optical power numbers are listed as dBm averages.
d
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a
Siemens sales associates when determining maximum segment distances.
34
RUGGEDCOM RSG2100
Installation Manual, 11/2022, C79000-G8976-1040-20