Certification
6.2EMC and Environmental Type Tests
Description Test Levels
1 kV differential mode @ 1 MHz
Signal Ports 5 kV (Fail-Safe Relay Output)
DC Power Ports 5 kV
HV Impulse
AC Power Ports 5 kV
Signal Ports 2 kV
DC Power Ports 2 kV
Dielectric
Strength
AC Power Ports 2 kV
Damped
Oscillatory
Magnetic Field
Enclosure Ports 100 A/m
Environmental Type Tests
Test Description Test Levels Severity
Level
IEC
60068-2-1
Cold Temperature Test Ad -40 °C (-40 °F), 16 Hours
IEC
60068-2-2
Dry Heat Test Bd 85 °C (185 °F), 16 Hours
IEC
60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db 95% (non-condensing),
55 °C (131 °F), 6 cycles
IEC
60068-21-1
Vibration 2g @ 10-150 Hz
IEC
60068-21-2
Shock 30 g @ 11 ms
IEC
60068-2-78
Humidity (Damp
Heat, Steady State)
Test Cab 10 days @ 55 °C (131 °F)
and 93% Relative Humidity
IEC
60068-2-14
Change of Temperature Test Nb 5 Cycles, -40 to 85°
C (40 to 185° F)
IEC
60255-21-2
Bump 10 g @ 16 ms Class 1
IEC
60255-21-3
Seismic Method A, Class 2 Class 1
RUGGEDCOM RSG2100
Installation Manual, 11/2022, C79000-G8976-1040-20
45