Description of the device
4.6 SELECT/SET button
SCALANCE SC-600
36 Operating Instructions, 10/2021, C79000-G8976-C453-04
To define the fault mask, follow the steps below:
1. Switch to display mode D.
Display mode D is active if the "DM1" and "DM2" LEDs are lit green.
If another display mode is active, you will need to press the "SET/SELECT" button
repeatedly until the "DM1" and "DM2" LEDs are lit green.
2. Hold down the "SELECT/SET" button for 5 seconds.
After 2 seconds, the "DM1" and "DM2" LEDs start to flash for 3 seconds. At the same
time, the port LEDs go on one after the other.
After you have held down the button for 5 seconds, the current settings are stored as
the "good status".
If you release the button before the 5 seconds have elapsed, the previous fault mask
will be retained.