Technical specifications
8.2 Mechanical stability (in operation)
SCALANCE SC-600
70 Operating Instructions, 10/2021, C79000-G8976-C453-04
8.2 Mechanical stability (in operation)
Mechanical stability (in operation)
Device
IEC 60068-2-27 shock
IEC 60068-2-6 vibration
15 g, 11 ms duration
6 shocks per axis
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
SC6x2-2C
SC6x6-2C
8.3 Cable lengths
The following technical specifications apply to SCALANCE SC-600:
Cable
Permitted cable length
IE TP torsion cable
with IE FC Outlet RJ-45 + 10 m TP cord
0 to 45 m
+ 10 m TP cord
IE TP torsion cable
with IE FC RJ-45 Plug 180
0 to 55 m
IE FC TP Marine / Trailing / Flexible cable
with IE FC Outlet RJ-45 + 10 m TP cord
0 to 75 m
+ 10 m TP cord
IE FC TP Marine / Trailing / Flexible cable
with IE FC RJ-45 Plug 180
0 to 85 m
IE FC TP standard cable
with IE FC Outlet RJ-45 + 10 m TP cord
0 to 90 m
+ 10 m TP cord
IE FC TP standard cable
with IE FC RJ-45 Plug 180
0 to 100 m

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC-600
CategorySwitch
LanguageEnglish

Related product manuals