Upkeep and maintenance
7.2 Restoring the factory settings
SCALANCE SC-600
66 Operating Instructions, 10/2021, C79000-G8976-C453-04
7.2 Restoring the factory settings
NOTICE
Previous settings
If you reset, all the settings you have made will be overwritten by factory defaults.
NOTICE
Inadvertent reset
An inadvertent reset can cause disturbances and failures in the configured network.
Requirement
The device is in the startup phase.
NOTICE
Reset despite disabled "SELECT/SET" button
Using the "SELECT/SET" button, you can always reset the device parameters to the
factory defaults during the startup phase of the device. This applies also if the "Reset
to Factory Defaults" function was disabled in the configuration. This allows you to reset
the device to the factory defaults in an emergency.
If the function has been disabled in the configuration, it is only disabled on completion
of the startup phase.
Procedure
To reset the device to the factory defaults during the startup phase, follow the steps
below:
1. Turn off the power to the device.
2. Now press the "SELECT/SET" button and reconnect the power to the device while
holding down the button.
3. Hold down the button until the red error LED "F" stops flashing and is permanently lit.
4. Now release the button and wait until the fault LED "F" goes off again.
5. The device starts automatically with the factory defaults.
Restoring the factory defaults during operation
You can also reset the device to the factory defaults during operation, see section
"SELECT/SET button (Page 34)".

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC-600
CategorySwitch
LanguageEnglish

Related product manuals