Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
161
Table 2 has the following columns:
Event
The column contains the following values:
Cold/Warm Start
The device was turned on or restarted by the user.
Link Change
This event occurs only when the port status is monitored and has changed, see
"System > Fault Monitoring > Link Change".
Authentication Failure
This event occurs when attempting access with a bad password.
Power Change
This event occurs when power supply lines 1 and 2 are monitored. It indicates that
there was a change to line 1 or line 2. The event occurs when the PoE power supply
has failed, see "System > Fault Monitoring > Power Supply".
Spanning Tree Change
The STP or RSTP or MSTP topology has changed.
Fault State Change
The fault status has changed. The fault status can relate to the activated port
monitoring, the response of the signaling contact or the power supply monitoring.
Overlap AP Detection
(Only in access point mode)
This event is triggered when there is an entry in the overlap AP list.
WDS
(Only in access point mode)
The connection status of a WDS link has changed.
DFS
(Only in access point mode)
This event occurs if a radar signal was received or the DFS scan was started or
stopped.
WLAN General
(Only in access point mode)
This event occurs if a the channel bandwidth has changed.
WLAN Authentication Log
Forwarding of the entries from the WLAN Authentication Log to the system protocol
server.
WLAN De/Authentication
(Only in client mode)
With successful or failed WLAN authentication attempts.
iPCF Cycle Time
(Only in access point mode)
Only available when the KEY-PLUG is inserted.
This event occurs if too many clients are logged on for the set iPCF cycle time or if
some clients were not reached in one cycle.
iPCF Poll Size
Only available when the KEY-PLUG is inserted.
This event occurs if the PNIO data size is too large for transfer.
E-Mail
The device sends an e-mail. This is only possible if the SMTP server is set up and the
"SMTP client" function is enabled.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals