EasyManuals Logo
Home>Siemens>Wireless Access Point>SIMATIC NET SCALANCE W700 Series

Siemens SIMATIC NET SCALANCE W700 Series User Manual

Siemens SIMATIC NET SCALANCE W700 Series
317 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
162 Configuration Manual, 03/2015, C79000-G8976-C267-08
Trap
The device sends an SNMP trap. This is only possible if "System > Configuration"
SNMPv1 Traps" is enabled.
Log Table
The device writes an entry in the event log table.
Syslog
The device writes an entry to the system log server. This is only possible if the system log
server is set up and the "Syslog client" function is enabled.
Fault
The device triggers a fault. The error LED lights up.
Procedure
Follow the steps below to change entries:
1. Select the check box in the row of the required event. Select the event in the column
under the following actions:
E-mail
Trap
Log table
Syslog
Fault
2. Click the "Set Values" button.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals