4 Optimizing Safety Programs
Safety Programming Guideline
Entry ID: 109750255, V1.0, 10/2017
38
Siemens AG 2017 All rights reserved
4 Optimizing Safety Programs
4.1 Optimizing the compilation duration and runtime
Introduction
User programming protection by coded processing is an important part of a safety
program (see Chapter 5). The objective is to detect any data corruption in the
safety program and thus prevent non-safe states.
This protection program is generated during the compilation, which extends the
compilation duration. The protection program also extends the F-CPU's runtime as
the F-CPU additionally processes this program and compares the results with the
user program.
You will find the protection program that is automatically generated by the system
in the system block folder of your F-CPU.
Figure 4-1: Protection program
User-generated
F-blocks
System-generated
F-blocks
Some of the instructions that can be used in the safety program influence a fail-
safe controller's performance to a greater extent than others.
This chapter shows different options for reducing the compilation and program
runtime.

Other manuals for Siemens SIMATIC S7-1500T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-1500T and is the answer not in the manual?

Siemens SIMATIC S7-1500T Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC S7-1500T
CategoryController
LanguageEnglish

Related product manuals