Programming the OPC UA client blocks
5.10 Error numbers
CP 443-1 OPC UA
108 Operating Instructions, 01/2017, C79000-G8976-C427-02
Done
Error
ErrorID (hex)
Name
Meaning
0 1 B00080C3 The connection resources of the CPU are temporarily ex-
hausted.
0 1 B0009085 The maximum memory space for items (64000 bytes) of the
OPC UA client has been exceeded.
0
1
B000800A
The OPC client was not enabled in the configuration.
0 1 B0008723 The read/write job references a non-existent data area in a
DB.
0
1
B000F001
Two function blocks were called in one cycle.
0 1 B000F002 OPC UA session not yet established. Call the UA_Connect
block again.
0
1
B000F003
Communication error
0 1 B000F004 Invalid value for the "SyntaxID" parameter in the UDT
"UAAnyPointer"
0
1
B000F005
Invalid data type in UAAnyPointer
0 1 B000F006 Invalid value for the "RepetitionFactor" parameter in the UDT
"UAAnyPointer"
0
1
B000F007
Invalid operand area of UAAnyPointer
0 1 B000F010 Invalid operand area in a read or write job: Arrays of inputs,
arrays of outputs, arrays of memory bits, arrays of local data
and arrays of local data of the predecessor block are not
permitted.
0
1
B000F011
The bit offset must be zero.
0
1
B0010001
Wrong data packet in UA_Connect
0
1
B0010002
Invalid URL of a server end point
0
1
B0010003
Invalid value for Timeout
0 1 B0010004 Invalid value for SessionTimeout
0
1
B0010005
Invalid value for MonitorConnection
0
1
B0010006
Invalid transport profile
0
1
B0010007
Invalid server URI
0
1
B0010008
Invalid Security procedure
0
1
B0010009
Invalid Security profile
0
1
B001000A
Invalid value for UserIdentityToken
0
1
B001000B
Invalid application name
0 1 B001000C No connection establishment to partners with security func-
tions (no authentication if security functions are disabled).
Enable the security functions.
0 1 B0010101 Invalid format of the server end point URL. It must start with
"opc.tcp://".
0
1
B0010102
The path of the server end point URL is not supported.
0
1
B0010103
The client must not connect itself to the server of its own CP.
0
1
B0010104
Invalid port
0
1
B0010105
Invalid address. DNS is not supported.
0
1
B0020001
Wrong data packet in UA_NameSpaceGetIndex
0 1 B0030001 Wrong data packet in UA_NodeGetHandleList
0
1
B0030002
Invalid NodeID Identifier