3 Setting up functions 03/2013
3.4 Fault services
© Siemens AG 2006-2013 All Rights Reserved
3-116 SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
Function Description Type
Control monitors x -y of y
Number of
lines
The number in the display indicates the number
of lines per window that can be shown in this
menu. You can select up to 200 lines. A scroll
bar will then be displayed in the window.
DISPLAY
SELECTION
Name Names of the control monitors.
DISPLAY
Display indicating whether the control monitor
has triggers that are independent of the common
start date:
No display: No
Faded display: Yes, at least one
Normal display: Yes, all
DISPLAY
Memory
requirement
Used memory requirement of monitor for:
PLC trigger configurations
PLC trace configurations
PLC trace data
DISPLAY
Performance Currently used PLC performance. DISPLAY
Monitor runs on the machine or is inactive. DISPLAY
An exclamation point indicates that the
configuration currently stored is not yet effective
on the machine.
DISPLAY
Note
Use the PLC performance index to define the performance that may be used for
the PLC triggers. Each PLC trigger uses a certain number of performance points.
This enables you to control the extent to which the PLC can be used by the PLC
trigger.
The PLC performance index can be defined individually. The amount of memory
and the cycle time granted for SINUMERIK Integrate can vary as the
performance of the control and the processes executed in it vary.
Fig. 3-22: Exchanging addresses in notifications