03/2013 3 Setting up functions
3.4 Fault services
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
3-165
Function Description Type
Name Name of the trigger; can be entered by the user.
If the field remains empty or is deleted, the
system generates the "Time trigger" name.
If the name already exists, a consecutive
number is automatically added in parentheses.
If the name is too long, the number added can
only be seen in a tooltip.
DISPLAY
INPUT
(max. 100
characters,
all characters
are
permissible)
Execution
-
On the client
side
- On the
server side
With the client-side execution, it is defined that
when the time of the trigger on the PC at the
machine expires, then this signals the server in
order to execute the programmed actions in the
control monitor. All actions can be selected.
Triggering on the server side runs independently
of the machine. The machine can even be
switched-off. Only those actions can be
selected, which do not require any online data
from the machine.
SELECTION
DISPLAY
Reset
Without a specifically selected reset function, the
next maintenance job is always created again in
the programmed time grid - independent of
closing the maintenance job.
SELECTION
DISPLAY
- When
closing
a
maintenance
job
The restart of the trigger time can be set so that
this only starts again after the maintenance job
has been closed.
The next maintenance job is determined by the
time interval set from the time of closing. This
means that it does not make any difference if a
maintenance measure was performed too early
or too late.
- When
running
the control
monitor
A maintenance job can be initiated by the time
trigger described here - and also by other ORed
event triggers.
The restart of the trigger time is realized by each
trigger of the control monitor used which then
generates the maintenance job.
Start date A date can be entered individually to start the
intervals.
Once the interval has expired, the trigger is
initiated.
The date is limited to 24 months in the future
and 24 months in the past.
DISPLAY
INPUT
(Date format
with leading
zeros)