5
5.2 ”Speed setpoint” mode (P700 = 1) (from SW 2.0)
5-139
Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
5.2.6 Parameters for n–set operation
The following parameters are used for the general parameterization in
the ”speed setpoint” mode:
P8 Maximum speed
P9 Ramp–up time
P25 Override, acceleration
P58 Holding brake, brake opening time
P59 Speed, close holding brake
P60 Holding brake, brake delay time
P61 Holding brake, controller inhibit time
P700 Selector switch mode
P880 Normalizing N–SET
P930 Actual operating mode
P1426 Tolerance bandwidth, speed actual value
P1427 Delay time Nset reached
5.2.7 Terminal signals
It is not possible to feed back the terminal signals as was the case pre-
viously (pos mode). This is because the feedback signal byte (RMB) is
used to display the speed actual value.
The relevant bits of the control and status word in the n–set mode are
interlocked with the terminals using the appropriate parameterization
(P31/P32).
The status word is used to feed back the terminal signal
Status word (n–set).
––> ZSW.11: Feedback signal, terminal 1
––> ZSW.12: Feedback signal, terminal 2
5 Description of the Functions
02.9905.0305.03

Table of Contents

Other manuals for Siemens SIMODRIVE POSMO A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMODRIVE POSMO A and is the answer not in the manual?

Siemens SIMODRIVE POSMO A Specifications

General IconGeneral
BrandSiemens
ModelSIMODRIVE POSMO A
CategoryEngine
LanguageEnglish

Related product manuals