6
6.4 Bus monitor AMPROLYZER for PROFIBUS–DP
6-252
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
The following supplementary addresses are available:
S Speed setpoint:
FC00
hex
8 64512
dec
the same normalization as the speed
actual value
S Position actual value:
FC6A
hex
8 64618
dec
shift factor
= 6: 1 motor revolution 8 4 V ––> 75 W motor
= 4: 1 motor revolution 8 5 V ––> 300 W motor
S I
set
(n controller):
FC38
hex
8 64568
dec
the same normalization as the
current actual value
S I
set
(smoothed):
FC3A
hex
8 64570
dec
the same normalization as the
current actual value
Reader’s note
The signals are shown in Chapter 3.3.1.
6.4 Bus monitor AMPROLYZER for PROFIBUS–DP
The AMPROLYZER bus monitor can be used to diagnose, monitor and
trace data transfer in PROFIBUS networks.
AMPROLYZER (Advanced Multicard PROFIBUS Analyzer)
The software is freeware and is available from the Internet as follows:
––> http://www.ad.siemens.com/simatic–cs
––> search for the article number 338386
The self–extracting EXE file can be downloaded.
For more information on the AMPROLYZER bus monitor, please refer
to the information in the Internet and the files supplied.
J
Additional
possible
addresses
Description
Internet address
6 Fault Handling and Diagnostics