5
5.6 Parameters for SIMODRIVE POSMO A
5-200
Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
The factory setting of parameters for SIMODRIVE POSMO A can be
re–established if required.
Establish the factory default setting?
Set P970 from 1 to 0
Download is automatically acknowledged with P970 = 1
The parameters are now in the volatile memory (RAM).
After the parameters have been transferred into the non–volatile
memory, the factory default setting is loaded when powering up.
Set P971 from 0 to 1
Data save is automatically acknowledged with P971 = 0
For SIMODRIVE POSMO A, the following service functions are avail-
able with reference to parameters:
P980:78 Supported parameters
List of all supported parameters
P990:78 Changes with respect to the factory default setting
list of all of the parameters which have been
changed with respect to modified parameters
The following parameters are available for positioning motor identification:
P52 Hardware version
P53 Firmware version
P964:8 (from SW 1.4) Drive identification
Setting the factory
default
Service functions
for the
parameters
(refer to Chapter
5.6.2)
Parameters for
identification (refer
to Chapter 5.6.2)
5 Description of the Functions
02.9904.01