Description of the motors
2.3 Technical features and ambient conditions
1FT2 synchronous motors for SINAMICS S120
26 Configuration Manual, 03/2021, A5E50645584B AA
2.3.5 Environmental conditions
You can classify the environmental conditions for stationary use at weather-protected
locations according to the standard DIN EN 60721-3-3: 1995-09.
With the exception of environmental influences "Low air temperature", "Low air pressure",
and "Condensation", the motor complies with climate class 3K4.
Table 2- 1 Permissible environmental conditions for the motor based on climate class 3K4
Rate of temperature change
1)
4)
2
Wind-driven precipitation
(rain, snow, hail, etc.)
Averaged over a period of 5 min.
Conditions in mines are not considered.
A cooling system based on natural convection can be disturbed by unforeseen air movements.
4)
The limit value of 89 kPa covers applications at altitudes up to 1000 m.
Note
Installation instructions
The motor is not suitable for operation in the foll
owing environmental conditions:
In salt-laden or aggressive atmospheres
Outdoors
In a vacuum
In hazardous areas with a danger of explosion
You will find additional data on the environmental conditions, such as for transport and
storage of the motor, in Chapter "Preparation for use (Page 109)".